About this item
Process thermostats with integrated cooling system for dynamic temperature control within external circuits.
- Coloured TFT display for simultaneous indication of actual and set values and graphic illustration of the temperature profile
- Clear text menu navigation, six selectable languages DE, EN, FR, ES, IT and RU
- Management of heat transfer liquids with stored properties
- Easy input via cursor and soft keys. Additional Tmax key for overtemperature protection
- SelfCheck Assistant for system diagnosis
- Fully electronic continuous controller with PID action for internal and external control
- Self adapt function for determination of control parameters
- Programmer with 150 temperature/time segments that can be separated into 5 programs with digital display of pump pressure
The Thermostat comes with a PowerAdapt system enabling usage of the maximum possible amount of heat permitted by the power supply system; with a low-level and adjustable over-temperature protection with acoustic alarm for use with flammable and non-flammable liquids. An integrated powerful LAUDA Variopump (pressure pump) with 8 selectable output levels for control of outflow pressure.
USB and Ethernet interface equipped as standard, as well as a port for external PT100, second external PT100 feasible via interface module. Option for upgrading up to 2 additional interfaces (RS 232/485, Profibus, analogue, contact or EtherCAT module) and an integrated web server for browser based operation in local area networks via PC, tablet or smart phone, secure data transfer due to authentication procedure and encryption.
Remote fault indication through floating contact and an integrated and adjustable bypass. Not only does it incorporate a SmartCool system for energy-saving, digital - cooling management, including compressor on-off control, but more importantly a very small internal volume and big non-thermostated expansion vessel (cold fluid layer system) and Condenser cooling Water. Units utilise traditional refrigerants (HFCs) in accordance with European legislation to control F-gases (EU) 517/2014. Max. pumping pressure: 3,1 bar; flow rate: 65 L/min for all models except IN 4XTW/IN 8XTW: 3,1 bar; flow rate: 60 L/min, IN 1850XTN: 6 bar, flow rate: 120 L/min.
Specifications
- Catalog No:
- LAUDL002681
- LAUDL002677
- LAUDL002676
- LAUDL002675
- LAUDL002674
- LAUDL002673
- LAUDL002689
- LAUDL002687
- LAUDL002685
- LAUDL002683
- LAUDL002684
- LAUDL002680
- LAUDL002678
- Model:
- IN 2560 XTW
- IN 750 XT
- IN 550 XTW
- IN 550 XT
- IN 250 XTW
- IN 150 XT
- IN 1590 XTW
- IN 590 XTW
- IN 280 XTW
- IN 8 XTW
- IN 280 XT
- IN 1850 XTW
- IN 950 XTW
- Electrical:
- 400 V, 3/PE 50 Hz and 460 V, 3/PE 60 Hz
- 400 V, 3/PE 50 Hz and 460 V, 3/PE 60 Hz
- 400 V, 3/PE 50 Hz and 460 V, 3/PE 60 Hz
- 400 V, 3/PE 50 Hz and 460 V, 3/PE 60 Hz
- 230 V, 50 Hz
- 230 V, 50 Hz
- 400 V, 3/PE 50 Hz and 460 V, 3/PE 60 Hz
- 400 V, 3/PE 50 Hz and 460 V, 3/PE 60 Hz
- 400 V, 3/PE 50 Hz and 460 V, 3/PE 60 Hz
- 400 V, 3/PE 50 Hz and 460 V, 3/PE 60 Hz
- 400 V, 3/PE 50 Hz and 460 V, 3/PE 60 Hz
- 400 V, 3/PE 50 Hz and 460 V, 3/PE 60 Hz
- 400 V, 3/PE 50 Hz and 460 V, 3/PE 60 Hz
Specifications
Related Information
LAUDA Heating and Cooling Process Thermostats, INTEGRAL XT.pdf
Product Literature
Air cooled models
Product Information
- Catalog #Supplier #TypeTemperature RangeTemp. stabilityCapacityW×D×HAvailabilityPrice
- Heating and cooling process thermostat, 68 dB(A) noise level, IEC 60309, 5-pol, CEE, red, 16 A plug typeHeating and cooling process thermostat, 68 dB(A) noise level, IEC 60309, 5-pol, CEE, red, 16 A plug typeLAUDL002677L002677IN 750 XT−45...+220 °C±0,05 K4,8 - 17,2 L560×550×1325 mmLog in for availability1 * 1 ItemsSpecifications:
More
Specifications
ModelIN 750 XTEnvironmentally PreferableElectrical400 V, 3/PE 50 Hz and 460 V, 3/PE 60 Hz - Heating and cooling process thermostat, 66 dB(A) noise level, IEC 60309, 5-pol, CEE, red, 16 A plug typeHeating and cooling process thermostat, 66 dB(A) noise level, IEC 60309, 5-pol, CEE, red, 16 A plug typeLAUDL002675L002675IN 550 XT−50...+220 °C±0,05 K4,8 - 17,2 L560×550×1325 mmLog in for availability1 * 1 ItemsSpecifications:
More
Specifications
ModelIN 550 XTEnvironmentally PreferableElectrical400 V, 3/PE 50 Hz and 460 V, 3/PE 60 Hz - Heating and cooling process thermostat, 60 dB(A) noise level, CEE7/7 plug typeHeating and cooling process thermostat, 60 dB(A) noise level, CEE7/7 plug typeLAUDL002673L002673IN 150 XT−45...+220 °C±0,05 K2,5 - 8,7 L430×550×760 mmLog in for availability1 * 1 ItemsSpecifications:
More
Specifications
ModelIN 150 XTEnvironmentally PreferableElectrical230 V, 50 Hz - Heating and cooling process thermostat, 63 dB(A) noise level, IEC 60309, 5-pol, CEE, red, 16 A plug typeHeating and cooling process thermostat, 63 dB(A) noise level, IEC 60309, 5-pol, CEE, red, 16 A plug typeLAUDL002684L002684IN 280 XT−80...+220 °C±0,05 K4,8 - 17,2 L560×550×1325 mmLog in for availability1 * 1 ItemsSpecifications:
More
Specifications
ModelIN 280 XTEnvironmentally PreferableElectrical400 V, 3/PE 50 Hz and 460 V, 3/PE 60 Hz
Water cooled models
Product Information
- Catalog #Supplier #TypeTemperature RangeTemp. stabilityCapacityW×D×HAvailabilityPrice
- Heating and cooling process thermostat, 74 dB(A) noise level, 60 A plug typeHeating and cooling process thermostat, 74 dB(A) noise level, 60 A plug typeLAUDL002681L002681IN 1850 XTW–60...+220 °C±0,1 K12,6 - 34,4 L1100×895×1865 mmLog in for availability1 * 1 ItemsSpecifications:New Product
More
Specifications
ModelIN 2560 XTWEnvironmentally PreferableElectrical400 V, 3/PE 50 Hz and 460 V, 3/PE 60 HzNew Product - Heating and cooling process thermostat, 66 dB(A) noise level, IEC 60309, 5-pol, CEE, red, 16 A plug typeHeating and cooling process thermostat, 66 dB(A) noise level, IEC 60309, 5-pol, CEE, red, 16 A plug typeLAUDL002676L002676IN 550 XTW−50...+220 °C±0,05 K4,8 - 17,2 L560×550×1325 mmLog in for availability1 * 1 ItemsSpecifications:
More
Specifications
ModelIN 550 XTWEnvironmentally PreferableElectrical400 V, 3/PE 50 Hz and 460 V, 3/PE 60 Hz - Heating and cooling process thermostat, 57 dB(A) noise level, CEE7/7 plug typeHeating and cooling process thermostat, 57 dB(A) noise level, CEE7/7 plug typeLAUDL002674L002674IN 250 XTW−45...+220 °C±0,05 K2,5 - 8,7 L430×550×760 mmLog in for availability1 * 1 ItemsSpecifications:
More
Specifications
ModelIN 250 XTWEnvironmentally PreferableElectrical230 V, 50 Hz - Heating and cooling process thermostat, 52 dB(A) noise level, IEC 60309, 5-pol, CEE, red, 16 A plug typeHeating and cooling process thermostat, 52 dB(A) noise level, IEC 60309, 5-pol, CEE, red, 16 A plug typeLAUDL002683L002683IN 8 XTW25...320 °C±0,1 K3,6 - 9,8 L430×550×760 mmLog in for availability1 * 1 ItemsSpecifications:
More
Specifications
ModelIN 8 XTWEnvironmentally PreferableElectrical400 V, 3/PE 50 Hz and 460 V, 3/PE 60 Hz - Heating and cooling process thermostat, 69 dB(A) noise level, IEC 60309, 5-pol, CEE, red, 16 A plug typeHeating and cooling process thermostat, 69 dB(A) noise level, IEC 60309, 5-pol, CEE, red, 16 A plug typeLAUDL002678L002678IN 950 XTW−50...+220 °C±0,05 K4,8 - 17,2 L560×550×1325 mmLog in for availability1 * 1 ItemsSpecifications:
More
Specifications
ModelIN 950 XTWEnvironmentally PreferableElectrical400 V, 3/PE 50 Hz and 460 V, 3/PE 60 Hz - Heating and cooling process thermostat, 62 dB(A) noise level, IEC 60309, 5-pol, CEE, red, 16 A plug typeHeating and cooling process thermostat, 62 dB(A) noise level, IEC 60309, 5-pol, CEE, red, 16 A plug typeLAUDL002685L002685IN 280 XTW−80...+220 °C±0,05 K4,8 - 17,2 L560×550×1325 mmLog in for availability1 * 1 ItemsSpecifications:
More
Specifications
ModelIN 280 XTWEnvironmentally PreferableElectrical400 V, 3/PE 50 Hz and 460 V, 3/PE 60 Hz - Heating and cooling process thermostat, 62 dB(A) noise level, IEC 60309, 5-pol, CEE, red, 32 A plug typeHeating and cooling process thermostat, 62 dB(A) noise level, IEC 60309, 5-pol, CEE, red, 32 A plug typeLAUDL002680L002680IN 1850 XTW−50...+220 °C±0,05 K8 - 28,6 L760×650×1605 mmLog in for availability1 * 1 ItemsSpecifications:
More
Specifications
ModelIN 1850 XTWEnvironmentally PreferableElectrical400 V, 3/PE 50 Hz and 460 V, 3/PE 60 Hz - Heating and cooling process thermostat, 64 dB(A) noise level, IEC 60309, 5-pol, CEE, red, 16 A plug typeHeating and cooling process thermostat, 64 dB(A) noise level, IEC 60309, 5-pol, CEE, red, 16 A plug typeLAUDL002687L002687IN 590 XTW−90...+220 °C±0,05 K8 - 28,6 L760×650×1605 mmLog in for availability1 * 1 ItemsSpecifications:
More
Specifications
ModelIN 590 XTWEnvironmentally PreferableElectrical400 V, 3/PE 50 Hz and 460 V, 3/PE 60 Hz - Heating and cooling process thermostat, 65 dB(A) noise level, IEC 60309, 5-pol, CEE, red, 32 A plug typeHeating and cooling process thermostat, 65 dB(A) noise level, IEC 60309, 5-pol, CEE, red, 32 A plug typeLAUDL002689L002689IN 1590 XTW−90...+220 °C±0,05 K10 - 30,6 L760×650×1605 mmLog in for availability1 * 1 ItemsSpecifications:
More
Specifications
ModelIN 1590 XTWEnvironmentally PreferableElectrical400 V, 3/PE 50 Hz and 460 V, 3/PE 60 Hz